Branch panel 4c 2 section tested no roof building a disconnect ahu 21 tested no.
Electrical panel thermography report.
How infrared thermography works.
Thermal imaging infrared survey report sample.
5 15 2014 07 22 photo and identification location west electrical room panel refrigeration panel a mod116 equipment condensing unit 9 l1 28 l2 46 l3 46 fault current imbalance thermogram 13 06 2014 sp1 sp2 sp3 16 3 30 7 c 20 25 30.
This quantitative report of infrared inspection provides documentation of the problems abnormal conditions found in your equipment.
Thermography test of electrical panels infrared thermography is a test that can be utilised to identify unbalanced loads poor connections deteriorated insulation or any other issues in energized electrical panels or components without dismantling the components.
Rick turdubay certified infrared investigator b s.
Customer reference anot ab040315 2.
Panel mod150 sample report thermography inspection date.
Thermal imaging report inspection ref.
Ti electrical trending demo 2 electrical ti ltd ti electrical trending demo 1st jun 2012 client ti ltd site ti electrical trending demo trident court 1 oakcroft road chessington surrey kt9 1bd contact richard wallace richard thermalimaging co uk 0203 0442940.
Confidentiality copyright and reproduction.
Electrical room house panel incoming lugs.
Joe demonte senior thermography course instructor abstract there has existed in the past a misunderstanding that infrared thermography could be accomplished without the benefit of removing panel and or dead front covers on electrical apparatus.
Restricted commercial.
Title example electrical thermography report.
This would be wonderful from the standpoint of logistics manpower and labor hours.
Infrared electrical inspection report.
120 208v load 3 not possible to analyze 4.
Transformer t 4b tested yes 4 4th.
Panel control room 2pump 1 panel control room 2pump 2 panel.
Severity criteria are provided and the report will show you the electrical fault if it exists in the infrared image and it will also list all faults found in their order of importance for repair in the infrared electrical report.
Example electrical thermography report.
Customer a n other customer.
January 30 2017 by bob berry electrical thermography general what type of information should be included in an electrical thermographic report.
Branch panel 4b tested no 4th.
It uses subjective and objective evaluations to help you prioritize repairs that will give you the greatest return from this inspection and your maintenance.